High input power factor, low current harmonics, small voltage and current ripple, high conversion efficiency up to 94% and high density of module power.
Compatible with wide input voltage range 384V~528V to provide battery with stable charging.
Feature of CAN communication enable the EV charger to communicate with lithium battery BMS before starting the charge, making charging safer and battery life longer.
With Ergonomic appearance design and user-friendly UI including LCD display, TP, LED indication light, buttons.
With protection of overcharge, over-voltage, over-current, over-temperature, short circuit, input phase loss, input over-voltage, input under-voltage, etc.
Hot-pluggable and modularized design to make component maintenance simple and MTTR (Mean Time To Repair) reduced.
UL certificate issued by NB laboratory TUV.
Model No. |
APSP-48V 100A-480UL |
DC Output |
|
Rated Output Power |
4.8KW |
Rated Output Current |
100A |
Output Voltage Range |
30VDC~65VDC |
Current Adjustable Range |
5A~100A |
Ripple |
≤1% |
Stable Voltage Precision |
≤±0.5% |
Efficiency |
≥92% |
Protection |
Short circuit, Overcurrent, Overvoltage, Reverse Connection and Over-Temperature |
AC Input |
|
Rated Input Voltage |
Three-phase four-wire 480VAC |
Input Voltage Range |
384VAC~528VAC |
Input Current Range |
≤9A |
Frequency |
50Hz~60Hz |
Power Factor |
≥0.99 |
Current distortion |
≤5% |
Input Protection |
Overvoltage, Under-voltage, Overcurrent and Phase Loss |
Working Environment |
|
Working Temperature |
-20%~45℃, working normally; 45℃~65℃, reducing output; over 65℃, shutdown. |
Storage Temperature |
-40℃ ~75℃ |
Relative Humidity |
0~95% |
Altitude |
≤2000m, full load output; >2000m, please use it in accordance with the provisions of 5.11.2 in GB/T389.2-1993. |
Product Safety And Reliability |
|
Insulation Strength |
IN-OUT: 2200VDC IN-SHELL: 2200VDC OUT-SHELL: 1700VDC |
Dimensions And Weight |
|
Dimensions |
600(H)×560(W)×430(D) |
Net Weight |
55KG |
Ingress Protection Rating |
IP20 |
Others |
|
Output Plug |
REMA plug |
Cooling |
Forced air cooling |
Make sure that power cables are connected with grid in professional way.
Push the switch to power the charger on.
Press the Start button.
After the vehicle or battery is fully charged, press the Stop Button to stop charging.
Disconnect the REMA plug with the battery pack, and put the REMA plug and cable on the hook.
Push the switch to power the charger off.